Forum Post: RE: A quick test of creating cant in ORD - not fully satisfied...

$
0
0
Hi kivanc Must agree with the previous replies to this thread - the manual setting of equilibrium cant constant is critical to the deisgn of cant. I work in both standard UK 1432mm using 11.82 constant and broad gauge Northern Ireland 1600mm using 13.14. Currently I have the ability to switch between the two using predefined Project Defaults in SS2/4. Would apprecite the same functionality in ORD. Would note that this is something that CAN be calculated using gauge and width of rails - however knowledge of how cant is applied and how the constant is worked out is required, something that is likely to be difficult to write into the software, especially considering engineers using this know what is required already